193.174.19.232Abstract: S. Han, S. Zhang, W. Lv (2025)

Electric Power Systems Research, 247, 111835p. (2025) DOI:10.1016/j.epsr.2025.111835

Fault diagnosis of grid-connected NPC inverter based on information fusion and lightweight neural network

S. Han, S. Zhang, W. Lv

Open-circuit faults in grid-connected neutral point clamped (NPC) inverters are difficult to diagnose accurately due to their hidden nature and diverse fault modes. In order to distinguish faults, multiple diagnostic signals are usually required, but inputting too many diagnostic signals into the neural network will consume computing resources and response time. This paper proposes an efficient fault diagnosis method combining information fusion and a lightweight neural network.The “voltage between the midpoint of the upper and lower bridge arms†is defined as the fault detection signal, and it is fused with the current signal into a single gray image by using adaptive weighting fusion and un-threshold fusion recurrence plot. The hybrid attention mechanism of self-attention and convolution mix is introduced into the RepViT model to enhance the accuracy of model detail feature extraction and diagnosis. At the same time, the RepViT model is optimized using an asymmetric convolution structure to reduce the computational cost of the model. Experimental results show that the ACmix-RepViT model achieves 99.59% diagnostic accuracy with an average test time of 11.66 ms. Compared to RepViT m0.6, it improves accuracy by 1.71% and reduces test time by 18%. Compared to ResNet-34, it reduces parameters and FLOPs by 90%.

back


Creative Commons License © 2026 SOME RIGHTS RESERVED
The content of this web site is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 2.0 Germany License.

Please note: The abstracts of the bibliography database may underly other copyrights.

Ihr Browser versucht gerade eine Seite aus dem sogenannten Internet auszudrucken. Das Internet ist ein weltweites Netzwerk von Computern, das den Menschen ganz neue Möglichkeiten der Kommunikation bietet.

Da Politiker im Regelfall von neuen Dingen nichts verstehen, halten wir es für notwendig, sie davor zu schützen. Dies ist im beidseitigen Interesse, da unnötige Angstzustände bei Ihnen verhindert werden, ebenso wie es uns vor profilierungs- und machtsüchtigen Politikern schützt.

Sollten Sie der Meinung sein, dass Sie diese Internetseite dennoch sehen sollten, so können Sie jederzeit durch normalen Gebrauch eines Internetbrowsers darauf zugreifen. Dazu sind aber minimale Computerkenntnisse erforderlich. Sollten Sie diese nicht haben, vergessen Sie einfach dieses Internet und lassen uns in Ruhe.

Die Umgehung dieser Ausdrucksperre ist nach §95a UrhG verboten.

Mehr Informationen unter www.politiker-stopp.de.