193.174.19.232
Sensors, 25(5), 1535p. (2025) DOI:10.3390/s25051535
Introduction: Aortic valve disease (AVD) is an inflammatory, lipid infiltration and calcification disease that has been associated with changes in the conventional linear heart rate variability (HRV) indices showing a marked shift towards sympathetic predominance and a deterioration of the autonomic control. Objective: To explore the HRV dynamics in AVD patients through nonlinear methods by recurrence quantification analysis (RQA). Methods: In total, 127 subjects participated in a cross-sectional study categorized into three groups: healthy valve (HV), aortic valve sclerosis (AVSc), and aortic valve stenosis (AVS), as determined by echocardiographic assessment. HRV data were collected from five-minute ECG recordings at both a supine position and active standing. RQA indices were calculated using the Cross Recurrence Plot Toolbox. Results: In the supine position, patients with AVS exhibited larger determinism and trapping time than those with AVSc and HV. The analysis of these differences revealed that determinism and laminarity increased progressively from HV to AVS. In the same way, the magnitude of change (Delta) between positions decreased and presented the lowest values in AVS in most of the nonlinear indices. Conclusion: RQA indices of HRV in AVD patients indicate a rigidizing dynamic characterized by larger determinism and extended trapping times in fewer system states in relation to the severity of AVD. These findings establish a precedent for future perspective assessments for the implementation of these methods in medical software or devices.
back
© 2026 SOME RIGHTS RESERVED
The content of this web site is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 2.0 Germany License.
Please note: The abstracts of the bibliography database may underly other copyrights.

Ihr Browser versucht gerade eine Seite aus dem sogenannten Internet auszudrucken. Das Internet ist ein weltweites Netzwerk von Computern, das den Menschen ganz neue Möglichkeiten der Kommunikation bietet.
Da Politiker im Regelfall von neuen Dingen nichts verstehen, halten wir es für notwendig, sie davor zu schützen. Dies ist im beidseitigen Interesse, da unnötige Angstzustände bei Ihnen verhindert werden, ebenso wie es uns vor profilierungs- und machtsüchtigen Politikern schützt.
Sollten Sie der Meinung sein, dass Sie diese Internetseite dennoch sehen sollten, so können Sie jederzeit durch normalen Gebrauch eines Internetbrowsers darauf zugreifen. Dazu sind aber minimale Computerkenntnisse erforderlich. Sollten Sie diese nicht haben, vergessen Sie einfach dieses Internet und lassen uns in Ruhe.
Die Umgehung dieser Ausdrucksperre ist nach §95a UrhG verboten.
Mehr Informationen unter www.politiker-stopp.de.