193.174.19.232Abstract: B. Ren, Y. Luo, N. Zhou, Q. Wang (2024)

International Journal of Electrical Power and Energy Systems, 158, 109958p. (2024) DOI:10.1016/j.ijepes.2024.109958

Fault location in high-voltage direct-current grids based on panoramic voltage features and vision transformers

B. Ren, Y. Luo, N. Zhou, Q. Wang

This paper presents a novel fault location method designed for high-voltage direct-current (HVDC) grids equipped with quick-action protections and circuit breakers. The method relies on a very short data window of single-ended voltage signals, which allows the acquisition of necessary measurements before the ultra-fast fault-isolation stage. Through fault analysis of the simulated four-terminal HVDC grid, it is observed that the fault distance induces a unique transient response in the voltage signal. However, due to the complex mathematical representation of loop components and the multiple fault factors involved, a data-driven strategy is adopted for fault distance estimation. Based on this strategy, four signal processing techniques, including Gramian angular field, recurrence plot, Markov transition field, and continuous wavelet transform, are used to extract panoramic voltage features. Additionally, four advanced lightweight variants of vision transformers (ViT), including MobileViT, EfficientFormer, Efficient-Model, and EdgeViT, are considered for constructing the regression model. The optimal combination of panoramic voltage features and regression models for configuring the locator is determined by statistical evaluation. The results of semi-physical experiments based on real-time digital simulators demonstrate that the proposed method, first, can accurately estimate the fault distance, second, possesses robustness against high transition resistance, low sampling frequency, and strong noise interference, and third, is practically feasible.

back


Creative Commons License © 2024 SOME RIGHTS RESERVED
The content of this web site is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 2.0 Germany License.

Please note: The abstracts of the bibliography database may underly other copyrights.

Ihr Browser versucht gerade eine Seite aus dem sogenannten Internet auszudrucken. Das Internet ist ein weltweites Netzwerk von Computern, das den Menschen ganz neue Möglichkeiten der Kommunikation bietet.

Da Politiker im Regelfall von neuen Dingen nichts verstehen, halten wir es für notwendig, sie davor zu schützen. Dies ist im beidseitigen Interesse, da unnötige Angstzustände bei Ihnen verhindert werden, ebenso wie es uns vor profilierungs- und machtsüchtigen Politikern schützt.

Sollten Sie der Meinung sein, dass Sie diese Internetseite dennoch sehen sollten, so können Sie jederzeit durch normalen Gebrauch eines Internetbrowsers darauf zugreifen. Dazu sind aber minimale Computerkenntnisse erforderlich. Sollten Sie diese nicht haben, vergessen Sie einfach dieses Internet und lassen uns in Ruhe.

Die Umgehung dieser Ausdrucksperre ist nach §95a UrhG verboten.

Mehr Informationen unter www.politiker-stopp.de.