193.174.19.232Abstract: R. Guo, Y. Wang, J. Yan, H. Yan (2012)

Journal of Traditional Chinese Medicine, 32(4), 571–577p. (2012) DOI:10.1016/S0254-6272(13)60073-4

Recurrence quantification analysis on pulse morphological changes in patients with coronary heart disease

R. Guo, Y. Wang, J. Yan, H. Yan

Objective: To show that the pulse diagnosis used in Traditional Chinese Medicine, combined with nonlinear dynamic analysis, can help identify cardiovascular diseases.

Methods: Recurrence quantification analysis (RQA) was used to study pulse morphological changes in 37 inpatients with coronary heart disease (CHD) and 37 normal subjects (controls). An independent sample t-test detected significant differences in RQA measures of their pulses. A support vector machine (SVM) classified the groups according to their RQA measures. Classic time-domain parameters were used for comparison.

Results: RQA measures can be divided into two groups. One group of measures [ecurrence rate (RR), determinism (DEL), average diagonal line length (L), maximum length of diagonal structures (Lmax), Shannon entropy of the frequency distribution of diagonal line lengths (ENTR), laminarity (LAM), average length of vertical structures (TT), maximum length of vertical structures (Vmax)] showed significantly higher values for patients with CHD than for normal subjects (P < 0.05). The other measures (RR_std, L_std, Lmax_std, TT_std, Vmax_std) showed significantly lower values for the CHD group than for normal subjects (P < 0.05). SVM classification accuracy was higher with

RQA measures: With RQA (16 parameters) accuracy was at 88.21%, and with RQA (12 parameters) accuracy was at 84.11%. In contrast, with classic time-domain (15 parameters) accuracy was 75.73%, and with time-domain (7 parameters) accuracy was 74.70%.

Conclusion: Nonlinear dynamic methods such as RQA can be used to study functional and structural changes in the pulse noninvasively. Pulse signals of individuals with CHD have greater regularity, determinism, and stability than normal subjects, and their pulse morphology displays less variability. RQA can distinguish the CHD pulse from the healthy pulse with an accuracy of 88.21%, thereby providing an early diagnosis of cardiovascular diseases such as CHD.

back


Creative Commons License © 2024 SOME RIGHTS RESERVED
The content of this web site is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 2.0 Germany License.

Please note: The abstracts of the bibliography database may underly other copyrights.

Ihr Browser versucht gerade eine Seite aus dem sogenannten Internet auszudrucken. Das Internet ist ein weltweites Netzwerk von Computern, das den Menschen ganz neue Möglichkeiten der Kommunikation bietet.

Da Politiker im Regelfall von neuen Dingen nichts verstehen, halten wir es für notwendig, sie davor zu schützen. Dies ist im beidseitigen Interesse, da unnötige Angstzustände bei Ihnen verhindert werden, ebenso wie es uns vor profilierungs- und machtsüchtigen Politikern schützt.

Sollten Sie der Meinung sein, dass Sie diese Internetseite dennoch sehen sollten, so können Sie jederzeit durch normalen Gebrauch eines Internetbrowsers darauf zugreifen. Dazu sind aber minimale Computerkenntnisse erforderlich. Sollten Sie diese nicht haben, vergessen Sie einfach dieses Internet und lassen uns in Ruhe.

Die Umgehung dieser Ausdrucksperre ist nach §95a UrhG verboten.

Mehr Informationen unter www.politiker-stopp.de.